Relemac Overseas Inc.
1449/27, 30 Feet Road,
Durga Puri, Delhi-110093.
Phone :+91-11-65299900,            :+91-11-65299800.
Mobile : +91- 9312249900.
Fax     : +91- 9899174286.
“Relemac Cables” 3 core flat cables are manufactured for critical space requirement, protection against indefinite immersion water under specified conditions, protection against rain-water and ingress of small solid foreign bodies.Relemac 3 Core flat cables are produced from best quality electrolytic copper, which is drawn, annealed on-line and bunched on automatic machines to ensure flexibility and uniform resistance. The conductors are insulated with a special grade of PVC on sophisticated co-extrusion lines. Outer sheath consists of highly abrasion resistant PVC Compound impervious to grease, oil and water.

CABLE DESIGN:
Submersible Pump cables is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Relemac is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability


Note :

650/1100 VOLTS    RELEMAC 3CORE FLAT CABLES FOR SUBMERSIBLE PUMPS
CONDUCTOR
PVC INSULATION
PVC SHEATH
CURRENT Rating at 30 0 C
Amps.
Approx
Weight Kg./Km.
Nominal Area in Nos. & Dia. of wire Nominal Thickness Nominal Core Dia. Nominal Thickness
Approx. Overall Dimensions
Sq. mm. Nos. / mm mm mm mm
Thickness mm
Width mm
1.5 22/0.30 0.8 3.25 1.15 6.0 12.8 16 125
2.5 36/0.30 0.9 3.84 1.15 6.4 14.6 20 175
4.0 56/0.30 1.0 4.65 1.15 7.4 17.2 28 235
6.0 85/0.30 1.0 5.30 1.15 7.9 18.7 34 325
10.0 140/0.30 1.0 6.60 1.40 9.9 23.7 46 525
16.0 226/0.30 1.0 8.20 1.40 11.4 28.0 62 785
25.0 354/0.30 1.2 10.10 2.00 14.7 35.5 79 1270
35.0 495/0.30 1.2 11.50 2.00 16.2 39.5 98 1640
50.0 703/0.30 1.4 13.60 2.20 18.3 45.5 125 2080
70.0 440/0.45 1.4 15.30 2.20 20.0 51.0 156 2830
95.0 475/0.50 1.6 18.00 2.40 23.5 60.0 180 3620

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per Class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
  • 4 core and 5 core flat cables are available on request.

RELEMAC DOUBLE SHEATHED ROUND CABLES FOR SUBMERSIBLE PUMPS

650 / 1100 VOLTS
Nos. of cores and core area
Approx.
outside diameter
Nos. of cores and core area
Aprox. outside
diameter
Nos. X mm 2
mm
Nos. X mm 2
mm
3 X 1.5
10.0
4 X 1.5
10.8
3 X 2.5
11.0
4 X 2.5
12.2
3 X 4
13.0
4 X 4
14.1
3 X 6
14.6
4 X 6
16.0
3 X 10
18.0
4 X 10
20.8
3 X 16
21.2
4 X 16
23.4
3 X 25
26.0
4 X 25
28.8
3 X 35
28.3
4 X 35
31.5
3 X 50
33.5
4 X 50
37.3
3 X 70
37.8
4 X 70
42.2
3 X 95
43.5
4 X 95
48.8