“Relemac Cables” 3 core flat cables are manufactured for critical space requirement, protection against indefinite immersion water under specified conditions, protection against rain-water and ingress of small solid foreign bodies.Relemac 3 Core flat cables are produced from best quality electrolytic copper, which is drawn, annealed on-line and bunched on automatic machines to ensure flexibility and uniform resistance. The conductors are insulated with a special grade of PVC on sophisticated co-extrusion lines. Outer sheath consists of highly abrasion resistant PVC Compound impervious to grease, oil and water.
CABLE DESIGN:
Submersible Pump cables is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Relemac is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability
Note :
CONDUCTOR |
PVC INSULATION |
PVC SHEATH |
CURRENT Rating at 30 0 C
Amps. |
Approx
Weight Kg./Km. |
| Nominal Area in |
Nos. & Dia. of wire |
Nominal Thickness |
Nominal Core Dia. |
Nominal Thickness |
Approx. Overall Dimensions |
| Sq. mm. |
Nos. / mm |
mm |
mm |
mm |
Thickness mm |
Width mm |
| 1.5 |
22/0.30 |
0.8 |
3.25 |
1.15 |
6.0 |
12.8 |
16 |
125 |
| 2.5 |
36/0.30 |
0.9 |
3.84 |
1.15 |
6.4 |
14.6 |
20 |
175 |
| 4.0 |
56/0.30 |
1.0 |
4.65 |
1.15 |
7.4 |
17.2 |
28 |
235 |
| 6.0 |
85/0.30 |
1.0 |
5.30 |
1.15 |
7.9 |
18.7 |
34 |
325 |
| 10.0 |
140/0.30 |
1.0 |
6.60 |
1.40 |
9.9 |
23.7 |
46 |
525 |
| 16.0 |
226/0.30 |
1.0 |
8.20 |
1.40 |
11.4 |
28.0 |
62 |
785 |
| 25.0 |
354/0.30 |
1.2 |
10.10 |
2.00 |
14.7 |
35.5 |
79 |
1270 |
| 35.0 |
495/0.30 |
1.2 |
11.50 |
2.00 |
16.2 |
39.5 |
98 |
1640 |
| 50.0 |
703/0.30 |
1.4 |
13.60 |
2.20 |
18.3 |
45.5 |
125 |
2080 |
| 70.0 |
440/0.45 |
1.4 |
15.30 |
2.20 |
20.0 |
51.0 |
156 |
2830 |
| 95.0 |
475/0.50 |
1.6 |
18.00 |
2.40 |
23.5 |
60.0 |
180 |
3620 |
- The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per Class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
- 4 core and 5 core flat cables are available on request.
| RELEMAC DOUBLE SHEATHED ROUND CABLES FOR SUBMERSIBLE PUMPS |
 |
Nos. of cores
and
core area |
Approx.
outside
diameter |
Nos. of cores
and
core area |
Aprox.
outside
diameter |
Nos. X mm 2 |
|
|
|
3 X 1.5 |
10.0 |
4 X 1.5 |
10.8 |
3 X 2.5 |
11.0 |
4 X 2.5 |
12.2 |
3 X 4 |
13.0 |
4 X 4 |
14.1 |
3 X 6 |
14.6 |
4 X 6 |
16.0 |
3 X 10 |
18.0 |
4 X 10 |
20.8 |
3 X 16 |
21.2 |
4 X 16 |
23.4 |
3 X 25 |
26.0 |
4 X 25 |
28.8 |
3 X 35 |
28.3 |
4 X 35 |
31.5 |
3 X 50 |
33.5 |
4 X 50 |
37.3 |
3 X 70 |
37.8 |
4 X 70 |
42.2 |
3 X 95 |
43.5 |
4 X 95 |
48.8 |
|
|
|